Sensra · Observe
ψN 0.00 · Sensra
The live plasma state, reconstructed from every diagnostic.
No single diagnostic sees the whole plasma. Sensra fuses them into one state estimate every control cycle, with an honest error bar, and tells Plasmara when the twin has drifted.
Example state estimate
- Elongation κ
- 1.74 ± 0.02
- Vertical position
- +0.6 ± 0.3 cm
- q95
- 3.42 ± 0.08
- βN
- 2.06 ± 0.11
Illustrative values for an example device.
ψN 0.14 · Capabilities
What Sensra does.
Fusion
Multimodal fusion
Magnetics, interferometry, Thomson, ECE, bolometry and more in one estimate.
Edge
Control-rate output
Runs on Holoscan beside the device at control-cycle rates.
Uncertainty
Honest error bars
Every quantity carries its uncertainty, so Stellix and Quenra know what to trust.
Drift
Twin recalibration
Flags when the twin and the plasma disagree, and by how much.
Cleaning
Denoise and repair
Detects failed channels and fills gaps from the twin, marked as filled.
Replay
Archive mode
Run the same estimator over past campaigns for analysis.
ψN 0.29 · Diagnostics
Every sensor in, one state out.
Sensra state estimate · every control cycle
Shape, position, current profile, βN, q95, with uncertaintyDiagnostic families and typical sampling ceilings we plan to support first. Rates are illustrative; every device is different.
ψN 0.43 · How it works
How Sensra runs.
01Week 1
Map
Diagnostics mapped to the device model.
02Weeks 2–5
Train
Estimator trained on archive and twin data.
03Week 6
Replay
Run over recorded shots; compare with your reconstruction.
04After review
Stream
Live at the edge, in shadow first.
ψN 0.57 · Specification
Planned specification.
| Item | Plan | Status |
|---|---|---|
| Inputs | Magnetics first; profiles and imaging added per device | First |
| Outputs | Shape, position, current, βN, q95, profiles, each with uncertainty | First |
| Latency | Under 1 ms per estimate at the edge | Design target |
| Hardware | IGX/Jetson with Holoscan; TensorRT serving | Planned |
| Fallback | Marks degraded estimates; never hides a failed channel | First |
| Interfaces | Holoscan operators, IMAS IDS, REST for replay | First |
ψN 0.71 · In the loop
Where Sensra sits.
Sensra is the eyes of the loop: it feeds Stellix and Quenra, and recalibrates Plasmara after every shot.
Plasmara is the twin in the middle. Sensra keeps it honest against live diagnostics, Stellix trains control inside it, Quenra bounds every policy, and Synthos generates the rare shots none of them can wait for.
ψN 0.86 · Questions
Straight answers.
Does Sensra replace our equilibrium reconstruction?
No. It learns from your reconstruction and runs at control rates; your reconstruction stays the reference.
What if a diagnostic fails mid-shot?
Sensra marks the channel, widens the uncertainty and tells Quenra. It does not invent a clean signal.
Which diagnostics first?
Magnetics, then interferometry, ECE and Thomson. Others are added per device.
ψN 1.00 · Next step
Send us one campaign of shots. Get a calibrated twin back.
Share device geometry, coil and actuator limits, and the diagnostics from a recent campaign. We fit a Plasmara twin to it, replay your shots, and show where control and disruption avoidance could move first.