ψN 0.00 · How it works
From shot archive to guarded shot.
Five steps, the same for every device. The first three never touch the machine.
ψN 0.17 · Steps
A first program, step by step.
01Week 1
Describe the device
Geometry, coils, actuators, diagnostics and limits become one device model.
02Weeks 2–6
Fit the twin
Plasmara learns your device from physics and recorded shots, then replays them.
03Weeks 4–8
Estimate the state
Sensra turns raw diagnostics into a plasma state each control cycle.
04Weeks 6–12
Train and bound
Stellix trains in the twin. Quenra sets the envelope. Synthos fills the gaps.
05After review
Shadow, then run
Recommendations next to your PCS, then bounded control after review.
ψN 0.33 · Responsibilities
Clear lines between our work and yours.
| Step | Fusalis does | Your team does |
|---|---|---|
| Describe | Builds the device model and checks the archive | Shares geometry, limits, diagnostics, shots |
| Twin | Fits and validates Plasmara against recorded shots | Reviews replay error per signal |
| Observe | Runs Sensra on recorded and live data | Confirms diagnostic mapping and calibration |
| Train | Trains Stellix, builds Quenra envelope, generates Synthos scenarios | Sets actuators, limits and test plan |
| Run | Shadow mode, then bounded control | Approves each step; PCS stays fallback |
ψN 0.50 · Configuration
One file describes the program.
Everything Fusalis is allowed to do on a device is written down, versioned and signed.
- Which actuators a policy may command.
- Hard limits that come from your engineering, not from us.
- Who approves each step from replay to bounded control.
device: demo-tok
twin: plasmara/demo-tok@2026.11.4
estimator: sensra/magnetics+ece+thomson
policy: stellix/shape-hold@0.9
guardrail:
model: quenra/demo-tok@2026.11.2
ramp_down_at_risk: 0.7
actuators:
allowed: [pf3, pf4, vertical_coil]
current_cap_frac: 0.95
mode: shadow # replay | shadow | bounded
approvers: [head_of_plasma_control]ψN 0.67 · Outcomes
What a first program should leave you with.
Weeks 2–6
A calibrated twin
Replay error reported per signal, so you know where to trust it.
Shadow
A shadow record
Every recommendation next to what the PCS did, shot by shot.
Review
A decision
Evidence to move to bounded control, or a clear list of what still blocks it.
ψN 0.83 · Questions
Straight answers.
How many shots do you need?
Hundreds help; a few dozen well-instrumented shots are enough to start a twin. Synthos fills rare regimes from the twin itself.
Can we stop at the twin?
Yes. Many programs will start with Plasmara and Sensra for analysis and add control later.
What runs at the device?
Sensra and Quenra, and later a Stellix policy, on edge hardware beside your control system. Training stays on GPU servers.
ψN 1.00 · Next step
Send us one campaign of shots. Get a calibrated twin back.
Share device geometry, coil and actuator limits, and the diagnostics from a recent campaign. We fit a Plasmara twin to it, replay your shots, and show where control and disruption avoidance could move first.